If you are a college or university looking to setup a complete lab. Please contact us with your details for custom quotation. [email protected]

Transmission Line Simulator

We are the leading manufacturer and supplier of Transmission Line Simulator. Now accepting bulk orders for government tenders in every major country around the globe.

Description:

The Transmission Line Simulator investigates single-phase and three-phase transmission lines. The configurable simulated transmission lines allow realistic studies of short, medium and long-distance transmission lines under variable load and power factor conditions, as well as with inserted faults. The console is divided into two control panels, each with detailed mimic diagrams. The upper panel has a single phase transmission line equivalent circuit, and the lower panel a three-phase transmission line. The lines may be loaded by the resistive, capacitive and inductive loads included. The effects can be monitored by instruments at the send and receive ends of the transmission lines.

Learning Outcomes

  • Single-phase line:
  • Short-line investigation
  • Medium or long-line investigation (nominal ‘Tee’ and ‘Pi’ methods)
  • Effect of power and reactive power flow on voltage drop and transmission angle
  • Medium/long-line investigation of a natural load of a line
  • Voltage regulation at constant load and power factor Three-phase lines:
  • Per-unit values
  • Unbalanced loads and the neutral connection
  • Fault simulation and line protection studies
  • Parallel feeders and multi-section lines

Specifications

ATICO is committed to a programme of continuous improvement; hence we reserve the right to alter the design and product specification without prior notice.
Nett dimensions and weight: 1850 mm long x 1870 mm high x 960 mm front to back and 750 kg
Approximate packed volume and weight: 5 m3 and 950 kg
Line simulation: Inductors, with three-phase line represented in per-unit values
Three-phase lines: Five sections, each at 0.15 p.u. value: 75 km of 132 kV line on a 100 MVA base
One section at 0.25 p.u. value: 125 km of 132 kV line on a 100 MVA base
Three-phase load banks: Resistive, inductive and capacitive
Other controls and instrumentation:
• Phase angle meter for single-phase and three-phase
• Fault switch
• Single-phase and three-phase selectable capacitor banks for p and T networks
• Switchable neutral from transformer secondary
Protection relay: Overcurrent relay

Operating Conditions

  • Operating environment: Laboratory environment
  • Storage temperature range:–25°C to +55°C (when packed for transport)
  • Operating temperature range: +5°C to +40°C
  • Operating relative humidity range: 80% at temperatures < 31°C decreasing linearly to 50% at 40°C
Tell us Your Requirements

Sending your message...